AC size calculator: how many BTUs do you need?
Enter a room's size to get ENERGY STAR's recommended cooling capacity in BTU per hour and tons. This is a rule-of-thumb estimate for room (window or portable) air conditioners. For a whole-house central AC or heat pump, the right size comes from an ACCA Manual J load calculation, not square footage.
Room AC size estimator
Chart and adjustments: ENERGY STAR, Room Air Conditioners: “Properly Sized Room Air Conditioners”. Rounding down to the nearest thousand: ENERGY STAR, “How To Choose the Right Sized Window AC” (2024). Capacities assume an 8-foot ceiling. 1 ton = 12,000 BTU/hr. Rule-of-thumb estimate only; see the Manual J note below.
Quick answers for common rooms
| Room (average sun, 2 people) | Area | ENERGY STAR capacity | Tons |
|---|---|---|---|
| Small bedroom, 10 × 12 ft | 120 sq ft | 5,000 BTU/hr | 0.42 |
| Primary bedroom, 14 × 16 ft | 224 sq ft | 6,000 BTU/hr | 0.50 |
| Living room, 16 × 20 ft | 320 sq ft | 8,000 BTU/hr | 0.67 |
| Studio apartment, 20 × 25 ft | 500 sq ft | 12,000 BTU/hr | 1.00 |
| Open living/dining, 25 × 30 ft | 750 sq ft | 18,000 BTU/hr | 1.50 |
| Large bonus room, 24 × 40 ft | 960 sq ft | 18,000 BTU/hr | 1.50 |
From the chart below, before adjustments. Add 10% for a very sunny room, 600 BTU/hr per extra regular occupant, and 4,000 BTU/hr for a kitchen. Source: ENERGY STAR, Room Air Conditioners: “Properly Sized Room Air Conditioners”.
ENERGY STAR room AC sizing chart
| Area to be cooled (sq ft) | Capacity needed (BTU/hr) | Tons |
|---|---|---|
| 100 up to 150 | 5,000 | 0.42 |
| 150 up to 250 | 6,000 | 0.50 |
| 250 up to 300 | 7,000 | 0.58 |
| 300 up to 350 | 8,000 | 0.67 |
| 350 up to 400 | 9,000 | 0.75 |
| 400 up to 450 | 10,000 | 0.83 |
| 450 up to 550 | 12,000 | 1.00 |
| 550 up to 700 | 14,000 | 1.17 |
| 700 up to 1,000 | 18,000 | 1.50 |
| 1,000 up to 1,200 | 21,000 | 1.75 |
| 1,200 up to 1,400 | 23,000 | 1.92 |
| 1,400 up to 1,500 | 24,000 | 2.00 |
| 1,500 up to 2,000 | 30,000 | 2.50 |
| 2,000 up to 2,500 | 34,000 | 2.83 |
Source: ENERGY STAR, Room Air Conditioners: “Properly Sized Room Air Conditioners”. Tons = BTU/hr ÷ 12,000. Where a room sits exactly on a row boundary (say 150 sq ft), we use the smaller row, since ENERGY STAR warns against oversizing.
Method: the four ENERGY STAR adjustments
- Measure the room in feet (length × width; split odd shapes into rectangles and triangles) and find its row in the chart.
- Heavily shaded room: reduce capacity by 10%. Very sunny room: increase it by 10%.
- More than two people regularly in the room: add 600 BTU/hr for each additional person.
- Kitchen: add 4,000 BTU/hr.
Then round the total down to the nearest thousand. That's the size to shop for. We apply the 10% sun adjustment to the chart value before adding the people and kitchen allowances, in the order ENERGY STAR lists them.
Sources: ENERGY STAR, Room Air Conditioners: “Properly Sized Room Air Conditioners”; ENERGY STAR, “How To Choose the Right Sized Window AC” (2024).
Worked example
A 12 ft × 20 ft family room is 240 sq ft, which falls in the 150 up to 250 sq ft row: 6,000 BTU/hr. It gets afternoon sun (+10% = +600), and four people regularly use it (two extra × 600 = +1,200). Total: 6,000 + 600 + 1,200 = 7,800 BTU/hr, or 0.65 tons. Rounded down to the nearest thousand, ENERGY STAR's method points to a 7,000 BTU/hr unit. If your shortlist doesn't have that exact size, pick the closest one rather than a much bigger one.
Assumptions and limits
- This is a rule-of-thumb estimate, not an engineering load calculation. It ignores insulation, window area and direction, air leaks, ducts and local design temperatures, all of which a Manual J accounts for.
- ENERGY STAR's capacities assume an 8-foot ceiling. Rooms with higher ceilings have more air to cool.
- The chart covers 100 to 2,500 sq ft. Below 100 sq ft we show the smallest listed size; above 2,500 sq ft we don't estimate a room unit.
- We don't add any climate-zone adjustment because ENERGY STAR's chart doesn't include one. Climate is one of the things a Manual J handles properly.
- Bigger isn't better: an oversized unit costs more, wastes energy and cools the room before it removes humidity, so it feels damp and clammy (ENERGY STAR); oversized systems can be noisy, uncomfortable and lead to mold (DOE).
FAQ
What size AC do I need for my room?
Use ENERGY STAR's chart: find the room's square footage, read the capacity, then adjust for sun, people and kitchen use. For example, a 150 to 250 sq ft room needs about 6,000 BTU/hr and a 450 to 550 sq ft room about 12,000 BTU/hr (1 ton).
How many BTUs is a ton of air conditioning?
One ton of cooling is 12,000 BTU per hour. A 24,000 BTU/hr unit is 2 tons; a 36,000 BTU/hr unit is 3 tons.
Can I size central air by square footage?
Only as a rough first guess. DOE calls “one ton per 400 to 500 square feet” a commonly accepted old estimate that ignores your local climate and how well the house is sealed and insulated, and notes one ton can cover 800 to 1,000 sq ft in a very efficient house. DOE says to insist your contractor uses ACCA Manual J to size the system.
Is a bigger air conditioner better?
No. ENERGY STAR warns that an oversized unit costs more, wastes energy and can cool the room before it removes humidity, leaving it damp and clammy. DOE adds that oversized systems can be noisy, provide inadequate comfort and lead to mold and poor indoor air quality.
How much extra capacity does a kitchen need?
ENERGY STAR says to add 4,000 BTU/hr if the unit is used in a kitchen. A heavily shaded 120 sq ft kitchen works out to 5,000 − 10% + 4,000 = 8,500 BTU/hr; rounded down, look for an 8,000 BTU/hr unit.
What is a Manual J load calculation?
Manual J is the Air Conditioning Contractors of America (ACCA) procedure for calculating a home's heating and cooling loads, recognized as an ANSI standard. It calculates loads from the home's construction, windows, ducts and local weather data. ACCA notes a load calculation to Manual J is required by national building codes and most state and local jurisdictions.
Next: what a new system costs and saves in your state, in AC replacement cost by state, the SEER2 savings calculator or the AC running cost calculator.
Sources: ENERGY STAR, Room Air Conditioners: “Properly Sized Room Air Conditioners”; ENERGY STAR, “How To Choose the Right Sized Window AC” (2024); U.S. DOE, Guide to Home Heating and Cooling (PDF); U.S. DOE Building Science Education, “Proper Sizing of HVAC Systems”; ACCA, Manual J Residential Load Calculation (ANSI/ACCA 2 Manual J – 2016).
Get free AC replacement quotes
Get free quotes from local HVAC pros. By submitting, you agree your information will be shared with Polyares and its contractor partners, who may contact you by phone, text or email about your project. See our privacy policy and disclosure.