SEER2 savings calculator

Is a higher-efficiency AC worth the extra cost? Going from the federal minimum to 18 SEER2 saves about $125/yr in Florida but only $8/yr in Washington for the same 2,000 sq ft home. Compare any two ratings for your state below.

Compare two AC efficiencies

Option A cooling cost / yr–
Option B cooling cost / yr–
Savings / yr–
Savings over ownership–
Payback on extra cost–

Option A defaults to your state's federal minimum for a new split-system AC; price defaults to the state's EIA average residential price (August 2026 YTD). Climate: NOAA state cooling degree days, 1991–2020. Payback appears once you enter the price difference between two real quotes. How this works.

How much less electricity does a higher SEER2 use?

Cooling electricity scales with 1 ÷ SEER2, so the percentage saved doesn't depend on your climate. Only the dollars do. Compared with a 14.3 SEER2 unit (the minimum in the South), 16 SEER2 uses 11% less cooling electricity, 18 SEER2 uses 21% less, and 20 SEER2 uses 28% less. Against the 13.4 SEER2 northern minimum, the cuts are 16%, 26% and 33%.

Gains shrink as ratings rise: going from 14.3 to 16 saves more per point than going from 18 to 20. Ratings come from standardized lab tests, so real-world savings depend on correct sizing, ductwork and installation.

Federal minimums: U.S. DOE regional standards. ENERGY STAR certified split-system central ACs need at least 15.2 SEER2 and 12.0 EER2: ENERGY STAR Version 6.2 central AC specification (PDF).

Worked example: Texas, 2,000 sq ft

Texas uses the 14.3 SEER2 southern minimum. With NOAA's statewide cooling degree days and average insulation, a 14.3 SEER2 system uses about 3,111 kWh a year for cooling, or $499 at 16.03¢/kWh. Moving up saves:

  • 15.2 SEER2 (ENERGY STAR): $30 a year
  • 16 SEER2: $53 a year
  • 18 SEER2: $103 a year, or $1,538 over 15 years

So if an 18 SEER2 quote costs $2,500 more than a 14.3 SEER2 quote, energy savings alone take about 24 years to cover the difference. Enter your own quotes above to check yours.

What SEER2 means, and the regional minimums

SEER2 is cooling output over a typical season divided by the electricity used. Since January 1, 2023, ratings come from DOE's updated test procedure, designed to better reflect real installations; DOE notes that SEER2 numbers are similar to the old SEER ratings but not directly comparable, so compare SEER2 with SEER2. DOE splits the country at 5,000 heating degree days: new split-system ACs must reach 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest.

DOE, 2023 central AC standards FAQ (PDF); U.S. DOE regional standards.

Yearly savings over the federal minimum, by state

StateMin SEER2Cooling cost at min15.2 (ENERGY STAR)16182018 SEER2, 15 yrs
Alabama14.3$356$21$38$73$101$1,098
Arizona14.3$521$31$55$107$149$1,607
Arkansas14.3$269$16$29$55$77$828
California14.3$335$20$36$69$96$1,033
Colorado13.4$65$8$11$17$22$250
Connecticut13.4$197$23$32$50$65$755
Delaware14.3$227$13$24$47$65$701
Florida14.3$607$36$65$125$173$1,873
Georgia14.3$296$18$31$61$84$912
Idaho13.4$75$9$12$19$25$288
Illinois13.4$202$24$33$52$67$775
Indiana13.4$184$22$30$47$61$704
Iowa13.4$139$16$23$36$46$533
Kansas13.4$263$31$43$67$87$1,008
Kentucky14.3$193$11$21$40$55$595
Louisiana14.3$396$23$42$81$113$1,222
Maine13.4$85$10$14$22$28$326
Maryland14.3$269$16$29$55$77$830
Massachusetts13.4$184$22$30$47$61$706
Michigan13.4$149$18$24$38$49$570
Minnesota13.4$89$11$14$23$29$340
Mississippi14.3$364$22$39$75$104$1,122
Missouri13.4$213$25$35$55$70$818
Montana13.4$33$4$5$8$11$126
Nebraska13.4$152$18$25$39$50$583
Nevada14.3$320$19$34$66$91$988
New Hampshire13.4$95$11$15$24$31$365
New Jersey13.4$245$29$40$63$81$938
New Mexico14.3$171$10$18$35$49$526
New York13.4$214$25$35$55$71$820
North Carolina14.3$244$14$26$50$69$751
North Dakota13.4$65$8$11$17$22$251
Ohio13.4$176$21$29$45$58$675
Oklahoma14.3$294$17$31$60$84$906
Oregon13.4$42$5$7$11$14$163
Pennsylvania13.4$176$21$29$45$58$676
Rhode Island13.4$193$23$31$49$64$741
South Carolina14.3$343$20$36$70$98$1,057
South Dakota13.4$119$14$19$30$39$455
Tennessee14.3$216$13$23$44$62$667
Texas14.3$499$30$53$103$142$1,538
Utah13.4$84$10$14$21$28$322
Vermont13.4$63$7$10$16$21$242
Virginia14.3$212$13$23$44$60$654
Washington13.4$31$4$5$8$10$120
West Virginia13.4$148$18$24$38$49$567
Wisconsin13.4$116$14$19$30$38$444
Wyoming13.4$46$5$7$12$15$176

Yearly savings vs a new minimum-efficiency unit for a 2,000 sq ft home with average insulation. EIA average residential price (August 2026 YTD); NOAA 1991–2020 cooling degree days. The last column is undiscounted and ignores future price changes. Estimates; see methodology.

What the numbers say

  • Where 18 SEER2 saves the most each year: Florida ($125), Arizona ($107), Texas ($103), Louisiana ($81), Mississippi ($75).
  • Where it saves the least: Washington ($8), Montana ($8), Oregon ($11), Wyoming ($12), Vermont ($16). Here, a minimum-efficiency or ENERGY STAR unit is usually the better buy.
  • A simple test: if the efficient unit costs more extra than the 15-year column for your state, it won't pay for itself on energy alone.
  • No federal tax credit covers a new central AC in 2026 (the 25C credit ended with equipment placed in service by December 31, 2025, per the IRS). Ask your utility about rebates.

Replacing an old unit instead? See AC replacement cost by state or the repair-or-replace calculator.

FAQ

What is SEER2?

SEER2 is the seasonal energy efficiency ratio measured under DOE's test procedure that took effect January 1, 2023: cooling delivered over a season divided by the electricity used. DOE changed the test to better reflect real-world installations, so SEER2 ratings are similar to, but not directly comparable with, older SEER ratings.

What is the minimum SEER2 in my state?

For new split-system central ACs, DOE requires 13.4 SEER2 in the North and 14.3 SEER2 in the Southeast and Southwest (states with fewer than 5,000 heating degree days). Our calculator pre-fills your state's minimum as option A.

Is 16 SEER2 worth it over 14.3?

16 SEER2 uses 11% less cooling electricity than 14.3. In Texas that's about $53 a year for a 2,000 sq ft home at 16.03¢/kWh, so it pays back only if the price difference is less than about $795 over 15 years.

Does a higher SEER2 rating save money in cold states?

Less. Savings scale with cooling hours: going to 18 SEER2 saves about $125 a year in Florida but $8 in Washington. In the North, pay for efficiency mainly if you value quieter, variable-speed comfort.

What SEER2 does ENERGY STAR require?

ENERGY STAR certified split-system central air conditioners need at least 15.2 SEER2 and 12.0 EER2 (Version 6.2 specification).